Laser Safety; Classification; Label Replacement - Omron ZG User Manual

2d profile measuring sensors
Hide thumbs Also See for ZG:
Table of Contents

Advertisement

Laser Safety

Various safety standards regarding laser products are stipulated depending on the
country of use.
Take safety measures according to each standard.

Classification

Standards and classification (*1)
JIS C 6802 2005 (Japan),
EN60825/IEC60825-1 (Europe)
ZG-WDS70/WDS22/WDS8T: Class 2M Class IIIB
ZG-WDS3T:
*1
For products exported to the countries other than Japan and Europe, different safety standards are applied
according to the countries. Check the LED safety regulations and standards of the relevant country.

Label Replacement

Use in the U.S.A.
Products relevant to FDA are supplied with labels that conform to FDA regulations.
When these products are used in the U.S.A., replace the warning label on the sensor
body with the FDA labels (supplied) referring to the figure below. Make sure that the
labels are affixed at the correct locations as indicated.
The ZG Series is intended to be fitted into a system as a terminal device. Follow the
following technical standards when fitting in the device.
* FDA: 21CFR 1040.10 and 1040.11
ZG User's Manual
FDA
(the United
States)
Class 2
Class II
Maximum Output of Laser Beam
Max. output 5 mW
Max. exposure (when optical
device is not used) 1 mW
Max. output 1 mW
Laser Safety