8-1

Communications Settings

8-1-1

Flowcharts

Set Mode
Monitor
Mode
Run Mode
Note The output of data after measurement is performed in Run
Measurement Commands
I/O via RS-232C Port
F150
Perform measurement
Output result
Note When RC/CS or Xon/off flow control is selected, if a
198
If the Normal communications mode is selected, data can be
output in non-procedural format to an external device via the
RS-232C port.
Command inputs cannot be received.
Command inputs can be received, but measurement results
are not output to external devices. Only the execution result
itself (i.e.: OK or ER) is output. If a command to read a set
value is input, that value will be output.
Both command input and measurement result output are sup-
ported.
mode will continue until all of the data has been output,
even if the mode is changed. Data output will not be inter-
rupted.
response is not received from the computer within a set
time, the F150 will conclude that there is a disconnection
or that the computer is not operating normally, and will
generate a timeout error. An error message will be dis-
played and the error terminal will turn ON.
Computer
Input command
*The BUSY terminal turns ON while a
measurements are being performed.
Receive result
Section 8-1