Measdata (Md): Measure Data - Omron F150-3 - MANUAL 2 Operation Manual

Vision sensor expert menu
Table of Contents

Advertisement

Input Commands
8-4-8

MEASDATA (MD): Measure Data

Input
Output
Example
The light level for the Intelligent Light Source (F150-
LTC20) connected to Camera 0 will be set in the way
shown below.
Output:
OK
MEASDATA is used to read measurement results.
MEASDATA
<Region_number> <Parameter>
or
MD
<Region_number> <Parameter>
• Specify a region number in the range 0 to 15.
• The meaning of the parameter will vary according to the
measurement method set for the region number speci-
fied. Refer to the parameter lists following.
Data correctly read:
Command not correct:
Input:
MD 0 2
Y coordinate measurement result for region 0 (gray
search) is read.
Output:
200.000
OK
The Y coordinate measurement value is 200.000.
Section 8-4
<Measurement_result>
OK
ER
213