Selecting Output Method for Error Terminal

5-8
Selecting Output Method for Error
Terminal
Procedure
174
During processing (i.e.: while BUSY terminal is ON), even if
the STEP terminal is turned ON, the F150 will not perform
measurement. It is possible to set the ERR terminal so that it
turns ON to indicate to an external device that input to the
STEP terminal could not be received.
Selection
ERR ON
During processing (i.e.: BUSY terminal ON), if the
(default set-
STEP terminal turns ON, the ERR terminal will be
ting)
turned ON and measurement will not be performed.
The next time a STEP signal is input with the BUSY
terminal OFF, the ERR terminal will go OFF.
OFF
During processing (i.e.: BUSY terminal ON), if the
STEP terminal turns ON, the ERR terminal will not
come ON. Measurement will not be performed.
1
Go to SYS/Error method.
System settings
Communications
Output
Device settings
Display
Set key operation
Switch menu
Startup mode
Error method
Version
Section 5-8
Details