Saving To Flash Memory - Omron F150-3 - MANUAL 2 Operation Manual

Vision sensor expert menu
Table of Contents

Advertisement

Saving to Flash Memory

Loading Data from the Computer
6-2
Saving to Flash Memory
5
Select Transfer/Receive File from the HyperTerminal
menu.
6
Specify where the file is to be saved and set the protocol to
Xmodem.
7
Select Receive. The data will be transferred from the F150
to the computer.
The F150 will generate a timeout error if no response is re-
ceived from the external device within 30 seconds. An er-
ror message will be displayed, and the error terminal will
turn ON.
1
Follow steps 1 to 3 in the above procedure to connect the
F150 and the computer.
2
Select Transfer/Send File from the HyperTerminal menu.
3
Select the file to be sent and set the protocol to Xmodem.
4
Select Send.
The data transfer screen will be displayed.
5
Execute the loading operation from the F150.
The F150 will generate a timeout error if no response is re-
ceived from the external device within 30 seconds. An er-
ror message will be displayed, and the error terminal will
turn ON.
Use the following memory to save set data to flash memory.
Flash memory data is loaded each time the F150 is started
up. Therefore, when settings have been changed, be sure to
save to flash memory before turning the power OFF. If the
power is turned OFF without saving, all of the setting changes
will be lost.
Section 6-2
181

Advertisement

Table of Contents
loading

This manual is also suitable for:

F150-3

Table of Contents