Output Calibration - Omron F150-3 - MANUAL 2 Operation Manual

Vision sensor expert menu
Table of Contents

Advertisement

Adjusting Images
Procedure
3-2-4

Output Calibration

Default Settings
50
1
Go to Adjust/BGS levels.
Shutter speed
Filtering
BGS levels
Calibration
Light control
2
Move the cursor to the upper-limit value and use the Left
and Right Keys to decrease or increase the value.
Press the Right Key to increase the smallest digit by 1 (use
with SHIFT Key to increase by 10). Press the Left Key to
decrease the smallest digit by 1 (use with SHIFT Key to de-
crease by 10).
3
Repeat the previous step to change the lower limit.
4
Select OK to exit this screen.
Calibration can be set to output the measurement results in
physical units, such as mm.
Set the relationship between the physical coordinates and the
camera coordinates to convert the measurement results from
pixels to physical units, such as µm, mm, or cm.
If calibration data is not set, the default settings will remain,
and measurements using the camera coordinates will be out-
put.
• Coordinate system: Left-handed system
• Origin: Upper left corner of screen
1
2
3
4