Saving/Loading System and Scene Data
Sample Operation for Personal Computer

!Caution

Saving Data to the Computer
180
As an example, this section explains how to perform data
transfers using HyperTerminal on Windows 95/98 or Windows
NT 4.0. It is assumed that an RS-232C cable is connected to
COM1 on the personal computer. If the COM number is differ-
ent, adapt the procedure accordingly. If different communica-
tions software is to be used, refer to the relevant manual for
that software. Data communications are performed according
to Xmodem (-CRC or -SUM) protocol.
Do not turn OFF the power or input a RESET signal while

a message is being displayed in any save or load opera-

tions. Data in memory will be destroyed, and the F150

may not operate correctly the next time it is started.

1
Connect the COM 1 port on the computer and the F150 us-
ing an RS-232C cable.
2
Make the F150 communications settings.
The default communications settings are as shown in the
following table. These settings can normally be used.
Item
Baud rate
Data length
Parity bits
Stop bits
Delimiter
3
Start the HyperTerminal program on the computer and
make the following communications settings.
The same communications settings must be used on both
the F150 and the modem on the computer.
Item
Speed
Data bits
Parity bits
Stop bits
Flow control
4
Execute the saving operation from the F150.
The data transfer screen will be displayed.
Setting
38,400 bps
8 (bits)
None
1 (bit)
CR
Setting
38,400 bps
8 (bits)
None
1 (bit)
None (Xmodem protocol is used.)