Input Commands
8-4-16

SCENE: Scene

Reading the Scene Number
Input
Output
Example
Switching the Scene
Input
Output
Example
8-4-17

SCNLOAD: Scene Load

Input
SCENE is used to read the currently displayed scene number
or switch scene.
SCENE
Data correctly read:
Command not correct:
Input:
SCENE
Output:
0
OK
Scene 0 is displayed.
SCENE
<Scene_number>
• Specify a scene number in the range 0 to 15.
Scene correctly switched:
Scene not correctly switched:
Input:
SCENE 2
The measurement scene is changed to scene 2.
Output:
OK
SCNLOAD is used to load scene data from a computer or
other external device.
SCNLOAD
<Scene_number>
• Specify a scene number in the range 0 to 15. The scene
data is transferred with Xmodem (-CRC or -SUM) proto-
col.
• When preparations to receive the data are completed, the
F150 will send a READY signal to the external device. Send
Section 8-4
<Scene_number>
OK
ER
OK
ER