Input Format
Surface Defect
Note The meanings of parameters 5 to 10 vary according to the
Parameter
05
Upper-left X
coordinate of
region (0 to 511)
06
Upper-left Y
coordinate of
region (0 to 483)
07
Lower-right X
coordinate of
region (0 to 511)
08
Lower-right Y
coordinate of
region (0 to 483)
09
---
10
---
9-3-13
1070: READ PARAMETER
Input
Begin
read word
15 to 12
+0
0001
+1
10's digit of
region
number
Parameter
00
Defect (0 to 255)
01
Upper limit of density value (0 to 255)
02
Lower limit of density value (0 to 255)
03
Element size (4 to 80)
04
Compare pitch (1 to 6)
05 to 10
See note
shape of the region.
Box
Line
X coordinate of
start point (0 to
511)
Y coordinate of
start point (0 to
483)
X coordinate of
end point (0 to
511)
Y coordinate of
end point (0 to
483)
Width (1 to 64)
---
Reads parameters for measurement regions. The data types
are the same as for command 1060. Refer to the parameter
lists above.
Bits
11 to 8
0000
0111
1's digit of
10's digit of
region
data type
number
Set all bits in words +2 to +4 to 0.
Meaning
Circumference
X coordinate of
center (0 to 511)
Y coordinate of
center (0 to 483)
Radius (1 to 512) Radius (1 to 512)
Width (1 to 64)
---
---
7 to 4
3 to 0
0000
1's digit of
data type
Section 9-3
Arc
X coordinate of
center (0 to 511)
Y coordinate of
center (0 to 483)
Width (1 to 64)
Start angle
(–180.00 to
180.00)
End angle
(–180.00 to
180.00)
Setting
Command code
Region No. (00 to 15)
Data type (00 to 14)
253