Exp: Expression - Omron F150-3 - MANUAL 2 Operation Manual

Vision sensor expert menu
Table of Contents

Advertisement

Input Commands
Example
Changing Currently Displayed Image
Input
Output
Example
8-4-3

EXP: Expression

Input
Output
Example
208
When a through or freeze image is being displayed, the mem-
ory number for the latest measurement image is output. If
there is no measurement image stored in memory, –1 will be
output.
Input:
DISPIMG
Output:
12
OK
The memory image number 12 is being displayed.
DISPIMG
<Memory_number>
• Specify a memory number in the range –1 to 23. If –1 is
specified, the display will change to a through or freeze
image, depending on the display settings. → Page 160
Command correctly executed:
Command not correct:
Input:
DISPIMG 8
Memory image number 8 is displayed.
Output: OK
EXP is used to read the results of output expressions.
<Output_type> <Output_number>
EXP
• Specify the following values for output type and output
number:
Item
Judgement
Data
Data correctly read:
Command not correct:
Input:
EXP 1 0
Output type
0
1
<Measurement_result>
OK
ER
Section 8-4
OK
ER
Output number
0 to 15
0 to 7