Omron CP1H-CPU - 05-2006 Operation Manual page 572

Cp1h cpu unit
Table of Contents

Advertisement

Auxiliary Area Allocations by Address
Address
Name
Words
Bits
A326
A326.04 Pulse Output
2 Output In-
progress Flag
A326.05 Pulse Output
2 No-origin
Flag
A326.06 Pulse Output
2 At-origin
Flag
A326.07 Pulse Output
2 Output
Stopped Error
Flag
A327
A327.00 Pulse Output
3 Accel/Decel
Flag
A327.01 Pulse Output
3
Overflow/
Underflow
Flag
A327.02 Pulse Output
3 Output
Amount Set
Flag
Function
ON when pulses are being output
from pulse output 2.
Cleared when operation starts or
stops.
OFF: Stopped
ON: Outputting pulses.
ON when the origin has not been
determined for pulse output 2 and
goes OFF when the origin has been
determined.
Turned ON when power is turned
ON.
Turned ON when operation starts.
OFF: Origin established.
ON: Origin not established.
ON when the pulse output PV
matches the origin (0).
OFF: Not stopped at origin.
ON: Stopped at origin.
ON when an error occurred while
outputting pulses in the pulse output
2 origin search function.
The Pulse Output 2 Output Stop
Error code will be written to A444.
OFF: No error
ON: Stop error occurred.
This flag will be ON when pulses are
being output from pulse output 3
according to an ACC(888) or
PLS2(887) instruction and the output
frequency is being changed in steps
(accelerating or decelerating).
Cleared when operation starts or
stops.
OFF: Constant speed
ON: Accelerating or decelerating
This flag indicates when an overflow
or underflow has occurred in the
pulse output 3 PV.
Cleared when operation starts.
OFF: Normal
ON: Overflow or underflow
ON when the number of output
pulses for pulse output 3 has been
set with the PULS(886) instruction.
Cleared when operation starts or
stops.
OFF: No setting
ON: Setting made
Settings
Status
Status
after
at star-
mode
change
---
---
Cleared
---
---
Cleared
---
---
Cleared
---
---
Cleared
---
---
Cleared
---
---
Cleared
---
---
Cleared
Appendix D
Write
Related
timing
flags, set-
tup
tings
Refreshed
---
when pulse
output
starts or
stops.
Refreshed
---
each cycle
during the
oversee-
ing pro-
cesses.
Refreshed
---
each cycle
during the
oversee-
ing pro-
cesses.
Refreshed
---
when ori-
gin search
starts.
Refreshed
when a
pulse out-
put stop
error
occurs.
Refreshed
---
each cycle
during
oversee
process.
Refreshed
---
when the
PV is
changed
by the
INI(880)
instruction.
Refreshed
when an
overflow or
underflow
occurs.
Refreshed
---
when the
PULS(886)
instruction
is exe-
cuted.
541