Current
5 V
0.420 A
consump-
tion
24 V 0.070 A
Power con-
5 V
0.762 A = 3.81 W
sumption
24 V
0.394 A = 9.46 W
Model
CP1H-X40DT-D
CP1H-X40DT1-D
CP1H-XA40DT-D
CP1H-XA40DT1-D
CP1H-Y20DT-D
CP1H-X40DR-A
CP1H-XA40DR-A
0.040 A
3
0.040 A
1
= 0.120 A
= 0.040 A
0.059 A
3
0.059 A
1
= 0.177 A
= 0.059 A
Restrictions for the Ambient Temperature
Restrictions in the System Configuration
Configure the system within the restrictions for the output load current, simul-
taneously ON inputs, and total power consumption.
Output load current
100%
67%
50 55
Ambient temperature ( C)
100%
75%
47 55
Ambient temperature ( C)
Power Supply Voltage Specifications for CPU Units with DC Power and
Transistor Outputs
When connecting CPM1A Expansion I/O Units with Relay Outputs to CPU
Units with DC Power and Transistor Outputs (CP1H-X40DT(1)-D, CP1H-
XA40DT(1)-D, and CP1H-Y40DT(1)-D), use a power supply voltage of
24 VDC 10% if connecting more than three Expansion I/O Units or if the
ambient temperature is greater than 45 C.
Mounting Restriction
When connecting CPM1A Expansion Units or Expansion I/O Units, provide a
space of approximately 10 mm between the CPU Unit and the first Expansion
Unit or Expansion I/O Unit.
CP1H CPU Unit
SYSMAC
IN
CP1H
AC100-240V
L1
L2/N
COM
01
03
05
07
09
11
01
03
05
07
09
11
BATTERY
00
02
04
06
08
10
00
02
04
06
08
10
POWER
PERIPHERAL
ERR/ALM
EXP
BKUP
MEMORY
00
01
02
03
04
06
00
01
03
04
06
COM
COM
COM
COM
05
07
COM
02
COM
05
07
DC24V0.3A
100CH
101CH
1CH
OUTPUT
OUT
10 mm
If sufficient space cannot be provided between the CPU Unit and the first
Expansion Unit or Expansion I/O Unit, reduce the temperatures in the above
derating curves for the output load current, number of simultaneously ON
inputs, and total power consumption by 5 C.
0.130 A
1
0.026 A
= 0.130 A
= 0.0520 A
0 A
0.044 A
= 0.088 A
Simultaneously ON inputs
100%
Input voltage:
26.4 V
55
Ambient temperature ( C)
Input voltage: 24 V
100%
Input voltage:
67%
26.4 V
47 55
Ambient temperature ( C)
Expansion I/O Units or Expansion Units
NC
NC
COM
01
03
05
07
09
11
01
03
05
07
09
11
NC
NC
COM
01
NC
NC
00
02
04
06
08
10
00
02
04
06
08
10
NC
NC
00
02
CH
CH
CH
CH
CH
IN
00
01
02
03
04
05
06
07
08
09
10
11
IN
00
01
02
03
04
05
06
07
CH
CH
00
01
02
03
04
05
06
07
08
09
10
11
00
01
02
03
04
05
06
07
CH
CH
OUT
00
01
02
03
04
05
06
07
OUT
00
01
02
03
04
05
06
07
40EDR
CH
CH
00
01
02
03
04
05
06
07
00
01
02
03
04
05
06
07
CH
CH
EXP
CH
NC
00
01
02
04
05
07
00
02
04
05
07
NC
00
01
02
NC
COM
COM
COM
03
COM
06
COM
01
03
COM
06
NC
COM
COM
COM
Section 1-2
2
Total: 0.762 A
2 A
2
Total: 0.394 A
1 A
Total: 13.27 W
30 W
Total power
consumption
100%
55
Ambient temperature ( C)
100%
75%
47 55
Ambient temperature ( C)
03
05
07
09
11
01
03
05
07
09
11
NC
NC
COM
01
03
05
07
09
11
01
04
06
08
10
00
02
04
06
08
10
NC
NC
00
02
04
06
08
10
00
02
CH
CH
CH
CH
08
09
10
11
IN
00
01
02
03
04
05
06
07
08
09
10
11
CH
08
09
10
11
00
01
02
03
04
05
06
07
08
09
10
11
CH
OUT
00
01
02
03
04
05
06
07
40EDR
CH
00
01
02
03
04
05
06
07
CH
EXP
CH
CH
04
05
07
00
02
04
05
07
NC
00
01
02
04
05
07
00
02
04
03
COM
06
COM
01
03
COM
06
NC
COM
COM
COM
03
COM
06
COM
01
03
COM
03
05
07
09
11
04
06
08
10
40EDR
EXP
05
07
06
23

Advertisement

Table of Contents
loading

Table of Contents