Monitor Two Types Of Data On A Single Monitor Screen - Hitachi WJ Series User Manual

Table of Contents

Advertisement

Chapter 10
10.3.6

Monitor Two Types of Data on a Single Monitor Screen

 How to easily monitor two types of data on a single monitor screen?
Q
A
Dual monitor [d050]
 Two monitor items can be set and the display can be switched by turning the JOG dial left/right.
 Set the function codes to be monitored to [b160] and [b161].
 Even if "Output frequency monitor [d001]" or "Output frequency scale conversion monitor
!
[d007]" is set to [b160]/[b161] and "Enable frequency changes through monitor display [b163]"
is set to "Enable (01)", frequency reference cannot be changed from [d050].
Code
[d050]
Dual monitor
[b160]
Dual monitor parameter 1
[b161]
Dual monitor parameter 2

Item
Monitors the two items set in [b160] and [b161].
001 to 030 correspond to [d001] to [d030].
001 to 030 correspond to [d001] to [d030].
SET
.
Esc
SET
JOG
.
Esc
SET
10-3-6
Monitor Functions
Description
Data of monitor parameter 1 set in [b160].
JOG
Data of monitor parameter 2 set in [b161].
Data
001 to 030
001 to 030