Three-Phase 200 V Class; Three-Phase 400 V Class - Hitachi WJ Series User Manual

Table of Contents

Advertisement

Chapter 17
17.1.3

Three-phase 400 V Class

Model name
C1-**** *1)
Applicable motor capacity
(4 poles) (kW)
Rated output
current (A) *2)
Overload current
rating
Output
Rated output voltage
Rated
capacity
(kVA)
Rated input
current(A) *3)
Rated input AC voltage
Input
*4)
Power supply
capacity (kVA) *5)
Carrier frequency variation *6)
Starting torque *7)
Without braking
Braking
resistor *8)
torque
With braking resistor
Minimum resistance value of
connectable braking resistor (Ω)
Cooling method
H (height) (mm)
Dimensions
W (width) (mm)
D (depth) (mm)
Degree of protection
Approximate weight (kg)
*1) The capacity code and voltage class are indicated on the model name. Others are omitted.
*2) Some models require current derating depending on the carrier frequency setting and ambient temperature. For
details, refer to "17.3 Current Derating". (Please contact us for models not described.)
*3) The rated input current is the value at the rated output current. The value changes according to the impedance
on the power supply side (wiring, breaker, input reactor option, etc.). The input current on the specification label
indicates the UL-certified current.
*4) Compliance with the Low Voltage Directive (LVD) is as follows. -Pollution degree 2, -Overvoltage category 3
*5) Power supply capacity is the value of the rated output current at 440 V. The value changes according to the
impedance on the power supply side (wiring, breaker, input reactor option, etc.).
*6) The setting range of "Carrier Frequency [b083]" is limited according to "Load Specification Selection [b049]". It is
recommended to set the carrier frequency setting equal or greater than the (maximum output frequency × 10)
Hz.
*7) The value is specified for the Hitachi standard motor controlled by the sensorless vector control at ND rating.
Torque characteristics may vary depending on the control mode and the motor used.
*8) The braking torque during regeneration is the average deceleration torque for the shortest deceleration (stopping
from 50 Hz). It is not continuous regenerative torque by the external force. The braking torque varies depending
on the loss of the motor. This value decreases when operating beyond the base frequency.
004H 007H 015H 022H 030H 040H 055H 075H 110H 150H
LD
0.75
1.5
ND
0.4
0.75
LD
2.1
4.1
ND
1.8
3.4
LD
ND
Three-phase 380 to 480 V (Output above the incoming voltage is not
LD
1.3
2.6
200V
ND
1.1
2.2
LD
1.7
3.4
240V
ND
1.4
2.8
LD
2.1
4.3
ND
1.8
3.6
Three-phase 380 to 480 V/allowable range of variation 323 to 528 V,
50 Hz (allowable range of variation 47.5 to 52.5 Hz)/60 Hz (allowable
LD
10.0
10.0
ND
10.0
10.0
LD
ND
100%: ≦ 50 Hz
50%: ≦ 60 Hz
150%
180
180
Self-
cooling
(without
FAN)
128
128
108
108
143.5
170.5 170.5 170.5 170.5 170.5
1.5
1.8
Specifications/Dimensions/Derating
2.2
3.0
4.0
1.5
2.2
3.0
5.4
6.9
8.8
4.8
5.5
7.2
120% 60 sec
150% 60 sec
possible.)
3.5
4.5
5.7
3.1
3.6
4.7
4.4
5.7
7.3
3.9
4.5
5.9
5.9
8.1
9.4
5.2
6.5
7.7
range of variation 57 to 63 Hz)
10.0
10.0
20.0
10.0
10.0
10.0
2.0 to 10.0 kHz
2.0 to 15.0 kHz
200% / 0.5Hz
70%: ≦
50 Hz
50%: ≦
60 Hz
100%
180
100
100
Forced air cooling (with FAN)
128
128
128
108
108
108
IP20 / UL open type
1.8
1.8
2.0
17-1-3
5.5
7.5
11
15
4.0
5.5
7.5
11
11.1 17.5
23.0
31.0 38.0
9.2
14.8
18.0
24.0 31.0
7.3
11.5
15.1
20.4 25.0
6.0
9.7
11.8
15.7 20.4
9.2
14.5
19.1
25.7 31.5
7.6
12.3
14.9
19.9 25.7
13.3 20.0
24.0
38.0 44.0
11.0 16.9
18.8
29.4 35.9
20.0 30.0
30.0
50.0 50.0
20.0 20.0
30.0
30.0 50.0
20%: ≦ 50 Hz
20%: ≦ 60 Hz
80%
100
70
70
70
128
260
260
296
140
140
140
180
155
155
165
2.0
3.5
3.5
4.5
18.5
15
35
296
180
165
4.5