Hitachi WJ Series User Manual page 480

Table of Contents

Advertisement

Appendix
A.1.3
Comparison of Control Circuit Terminal Block
 Spring clamp type terminal block is used for control circuit terminal block of both WJ200 and
A
WJ-C1, and the recommended wire diameter and terminal are the same. For details, refer to
"5.4.2 Recommended Wire Diameter and Wiring Method for Control Circuit Terminals".
Comparison of control circuit terminal block arrangement
WJ200
WJ-C1
* Terminals that have been added/changed electrical characteristics/changed functions compared to
WJ200 are outlined in white.
For those whose terminal symbols only have been changed, refer to the following comparison table.
* The following terminals have the same function/electrical specifications, but the terminal symbols have
been changed. Be careful when switching wiring.
Major changes of control circuit terminal function
Item
Symbol
Safety
GS1
input
GS2
EDM
output
11
signal
B phase
pulse
7
input
Power
supply
P24
for input
signal
Relay output
AL2 AL1 AL0
Pulse input
8
7
SP
SN
Modbus
communication
Voltage input [O] ⇒ [Ai1], Current input [OI] ⇒ [Ai2], Pulse input [EA] ⇒ [8]
Analog output [AM] ⇒ [Ao1], Pulse output [E0] ⇒ [Ao2]
WJ200
By turning ON the safety function
selector switch on the control
board, input terminals 3 and 4 are
switched to the safety function STO
input terminals [GS1] and [GS2].
By turning ON the EDM function
selector switch on the control
board, output terminal 11 is
switched to the EDM output
terminal.
Max. input frequency is 1.8 kHz.
Internal 24 VDC power supply
terminal for contact input.
Modbus
Intelligent input
communication
SN
7
6
SP
E0
EA
H
Pulse
Pulse
output
input
Intelligent input
6
5
4
3
2
H
Ai1 Ai2
L
Ao2 Ao1 CM2 12
Analog input
Pulse
output
and power
supply
Symbol
Safety function STO input terminals [ST1] and
ST1
[ST2] have been added as dedicated terminals.
ST2
In addition, [P24S] and [CMS] have been added
P24S
as dedicated power supply for functional safety.
Refer to "14.1 Using the Safety Function STO
CMS
(Safe Torque Off)" for more information.
In addition to the content shown on the left, in
case EDM function selector switch is ON, the
3rd and 4th of "Input terminal monitor [d005]"
11
switch to the status monitor of [ST1] and [ST2].
(Terminal functions assigned to input terminals
3 and 4 are not changed.)
Max. input frequency is 32 kHz.
7
(Other electrical characteristics are
unchanged.)
In addition to the content shown on the left, by
inputting an external 24 VDC power supply to
P24
this terminal and the [L] terminal, only the
control board can be started.
A-1-11
Logic power
supply and
common
5
4
3
2
1
L
O
OI
L
AM CM2 12
Intelligent
Analog input
Analog
output
and power
output
supply
Functional safety input and
power supply
Logic power supply
ST1 CMS ST2
and common
1
L
PLC
P24 P24S
11
AL2 AL1 AL0
Intelligent
Relay output
Analog
output
output
WJ-C1
PLC
P24
11