Chapter 9
Code
*1
[A044]
[b046]
*1
[H002]
*1
[H005]
[H020]/[H030]
*1
*1
[H021]/[H031]
*1
[H022]/[H032]
[H023]/[H033]
*1
[H024]/[H034]
*1
*1. "2nd-motor control [SET]" target parameter. The second control parameter is also subject to setting.
Item
Control mode selection
Direction reversal
protection selection
Async. Motor constant
selection
Async. Motor speed
response
Async. Motor constant R1
Async. Motor constant R2
Async. Motor constant L
Async. Motor constant I0
Async. Motor constant J
9-5-12
Description
Sensorless vector control (SLV)
Disable
Enable
(do not perform reverse rotation)
Applies the Hitachi standard
induction motor constant. "Async.
Motor constant [H020] to [H024]
apply.
Applies auto-tuning data.
"Async. Motor constant [H030] to
*1
[H034]
" apply.
Adjusts control responsiveness.
Increase this value to improve the
ability to follow the frequency
command.
Sets the motor constant.
Select whether to apply the Hitachi
standard induction motor constant
or auto-tuning data in "Motor
constant selection [H002]
Inverter Functions
Data
03
00
01
00
*1
"
02
1 to 1000 (%)
0.001 to 65.535 (Ω)
0.001 to 65.535 (Ω)
0.01 to 655.35 (mH)
0.01 to 655.35 (A)
*1
".
0.001 to 9999.000 (kgm
2
)