Hitachi WJ Series User Manual page 438

Table of Contents

Advertisement

Chapter 18
18.2.3
A Parameter Group
Code
Name
Frequency input
00: External operator POT
A001
source selection,
01: Control terminal
1st-motor
02: Parameter setting
03: Modbus communication
04: Option
Frequency input
A201
source selection,
06: Pulse input
07: Program function (EzSQ)
2nd-motor
10: Calculation function result
RUN command
input source
A002
selection, 1st-
01: Control terminal
motor
02: Keypad (RUN-key)
RUN command
03: Modbus communication
input source
04: Option
A202
selection, 2nd-
motor
Base frequency,
30.0 to Maximum frequency,
A003
1st-motor
1st-motor (Hz)
Base frequency,
30.0 to Maximum frequency,
A203
2nd-motor
2nd-motor (Hz)
Maximum
Base frequency, 1st-motor to
A004
frequency, 1st-
590.0 (Hz)
motor
Maximum
Maximum frequency, 2nd-
A204
frequency, 2nd-
motor to 590.0 (Hz)
motor
00: Switching between [Ai1]
02: Switching between [Ai1]
A005 [AT] selection
03: Switching between [Ai2]
A011 [Ai1] Start value
0.00 to 590.00 (Hz)
A012 [Ai1] End value
0.00 to 590.00 (Hz)
A013 [Ai1] Start rate
0 to [Ai1] End ratio (%)
A014 [Ai1] End rate
[Ai1] Start ratio to 100 (%)
[Ai1] Start value
00: [Ai1] Start value [A011]
A015
selection
01: 0 Hz or 0%
1 to 30: Set value × 2ms first-
Analog input
A016
filter time
31: 500 ms filter ±0.1Hz with
constant
00: Disable
EzSQ enable
A017
01: [PRG] terminal
selection
02: Always
00: 16 speeds ([CF1] to [CF4]
Multi-speed
A019
operation
01: 8 speeds (SF1] to [SF7] bit
selection
*1. In case that the optional remote operator with potentiometer (OPE-SR/OPE-SR mini) is connected.
*2. The default settings when initialize by setting 00/01/03 to "Initialize data selection [b085]".
*3. When in WJ200 high frequency compatible mode.
List of Parameters/Modbus Coil/Register Numbers
Data range
*1
(590.0)
and [Ai2]
*1
and POT
*1
and POT
order filter
hysteresis
binary input)
input)
18-2-5
Change
Initial
Set
during
value
value
Register No.
running
×
1201h
02/
01/
*2
01
×
2201h
×
1202h
02/
01/
*2
01
×
2202h
×
1203h
60.0/
50.0/
*2
50.0
*3
×
2203h
×
1204h
60.0/
50.0/
*2
50.0
*3
(590.0)
×
2204h
00
×
1205h
120Bh (High)
0.00
120Ch (Low)
120Dh (High)
0.00
120Eh (Low)
0
120Fh
100
1210h
01
1211h
1
1212h
00
1213h
00
×
1215h
Modbus communication
Data Range
Resolution
-
0 to 4, 6,7,10
-
1 to 4
-
1 to 4
-
300 to
Maximum
0.1
frequency,
1st-motor
300 to
Maximum
0.1
frequency,
2nd-motor
Base
frequency,
0.1
1st-motor to
5900
Maximum
frequency,
0.1
2nd-motor to
5900
0, 2, 3
-
0 to 59000
0.01
0 to 59000
0.01
0 to 100
1
0 to 100
1
0 to 1
-
1 to 31
-
0 to 2
-
0 to 1
-
Page
9-2-1
9-1-1
8-1-5
9-2-4
9-15-4
12-2-2
9-2-7

Advertisement

Table of Contents
loading

Table of Contents