Mirus for H2/H3 Graingage User's Guide
Absolute Moisture
Voltage
EM Frequency
EM Voltage
Moisture Probe
Temperature
Supply Voltage
H3 GrainGage Sensor Info Diagnostics
On the Sensor Info Diagnostics screen, live values are shown for the sensor in the
GrainGage.
Item
Calibration Name
3. GrainGage Diagnostics & Alerts
This is the raw moisture sensor reading without any offset
applied from a moisture curve. This is primarily used for
maintenance and troubleshooting.
This is a basic measure used for calculating grain moisture.
This value is typically between 3.5 and 4.1 mHz for an empty
chamber.
This is a basic measure used for calculating grain moisture.
This value is typically between 1.5 and 2.0 V for an empty
chamber.
This is the temperature measured by the moisture probe.
Since the sensed signal from moist grain changes with
temperature, the temperature measurement is used to apply
a correction in calculating grain moisture. It is measured in
degrees Celsius.
The amount of supply voltage the moisture sensor is
receiving. This value is typically between 11 and 14 volts.
H3 Sensor Info Diagnostics
The name of the Mirus calibration file in use.
Description
39