Weigh Bucket Load Cell Calibration; Calibrate Weigh Bucket - Juniper HarvestMaster mirus H2 Classic GrainGage User Manual

Table of Contents

Advertisement

Mirus for H2/H3 Graingage User's Guide

Weigh Bucket Load Cell Calibration

Weigh bucket calibration ensures the accuracy of the GrainGage's weight calculations.
This calibration should be done on initial setup and should not need to be calibrated
again unless repairs are needed on the GrainGage weigh system.

Calibrate Weigh Bucket

Use the weight calibration wizard and the larger weight (11 lb (5 kg)) included with the
GrainGage to calibrate the weigh bucket load cells.
To calibrate the weigh bucket,
1.
Park the combine on a level surface.
2.
Shut off the engine and keep the GrainGage powered on.
3.
Check that the weigh bucket is empty.
4.
From Home > Setup > H2 or H3 GrainGage, tap Calibration.
5.
Tap Calibration.
6.
Tap Bucket Weight Calibration.
7.
Select Open Calibration Wizard.
8.
Follow the on-screen instructions as shown below.
4. H2 or H3 Weight Calibration