Mirus for H2/H3 Graingage User's Guide
4.
Check the airflow through the air valves to ensure enough flow to quickly close
the gates and raise/lower the separator.
5.
Remove the air pressure and lift the separator up by hand to ensure it is not
binding.
6.
If the problem persists, contact the HarvestMaster Field Service Engineers. For
contact information,

Inaccurate Moisture or Constituent Data

1.
Check to ensure you are meeting the minimum weight threshold (see section
below).
2.
Inspect and clean the moisture blade or SCiO sensor glass dome.
3.
Touch the blade while watching the change in moisture readings within
Diagnostics.
4.
Check moisture temperature to ensure it is within 5–10 degrees of the ambient air
temperature.
5.
Check the supply voltage to ensure it is between 12 and 14 volts.
6.
Check to ensure the moisture blade and sensor mounting screws are secure.
7.
If the problem persists, contact the HarvestMaster Field Service Engineers. For
contact information,

Not Meeting Minimum Weight Threshold

The minimum weight threshold is the minimum amount of grain required for accurate
moisture and test weight data. By default, if the minimum weight threshold is not met,
moisture and test weight data will be recorded as zero and/or not included in the plot
average when taking sub-samples.
To ensure the plots are yielding enough grain to measure accurate data,
1.
Go to Setup > Info > Chamber Info.
Appendix B: Troubleshooting Mirus
see Contact a HarvestMaster Field Service
see Contact a HarvestMaster Field Service
Engineer.
Engineer.