Level Detect Diagnostics - Juniper HarvestMaster mirus H2 Classic GrainGage User Manual

Table of Contents

Advertisement

Mirus for H2/H3 Graingage User's Guide
Test Weight Diagnostics
Item
Test Weight
Chamber Weight
Insert Count
Load Cell 3
millivolts
Test Weight Q
Test Weight Tare
Check

Level Detect Diagnostics

On the Level Detect Diagnostics screen, Mirus displays the status of the Overflow Sensor.
It should be untripped when the weigh bucket is empty. When the overflow sensor is
disabled, the Diagnostics box will show the overflow sensor as untripped, and the status
will not change.
Note: Typically, only H2 Classics mounted on Wintersteiger Quantum or Classic Plus
combines are equipped with an overflow sensor that trips when grain is in close
proximity. 
3. GrainGage Diagnostics & Alerts
Description
Real-time test weight of grain in the test chamber.
Real-time weight of grain in the chamber. This value does not
include the weight of the chamber.
The number of inserts that have been set. 
The live operating voltage of the test weight load cell.
This multiplier corrects the test weight measurement based
on the slope and motion of the weighing platform.
Test weight value at the time the system last performed a
tare check.
41