Tare The Graingage - Juniper HarvestMaster mirus H2 Classic GrainGage User Manual

Table of Contents

Advertisement

Mirus for H2/H3 Graingage User's Guide
 Provides additional information for each screen (primarily for HarvestMaster
Field Service Engineers).
Each tab provides additional functionality detailed below.
Note: Tapping Tare in a Diagnostics tab tares the load cells and EM Moisture sensor.
Mirus does not allow taring of individual sensors. 
The icon panel across the top of the Diagnostics dialog box allows you to access each
diagnostic category. All Diagnostics screens show the Tare and Open All (or Close All)
buttons, as explained in the following table:
Item
Use the Tare button to zero all load cells and the moisture sensor. The
tare process is as follows:
Tare button
Use the Open All button to open all the gates. With all the gates open,
the grain flows straight through the GrainGage unimpeded. Use this
when you need to glean off border plots. In this mode, the button
Open All
changes to Close All. No data will be collected or recorded in this
button
mode. Some machines can divert the air directly to the grain tank
before it reaches the GrainGage. It is best to completely bypass the
GrainGage rather than opening all the gates, when this is an option.
Close All
Use the Close All button to put the GrainGage into Harvest Mode and
button
return to measuring the grain and recording data.

Tare the GrainGage

In the Diagnostics box,
1.
Tap Tare.
2.
After the tare is complete, tap the check icon
Note: HarvestMaster recommends that the combine be turned on with the
throttle turned up and the thresher running. Taring should be the last thing you
do before you start to harvest. For improved data quality, do not tare within a field
3. GrainGage Diagnostics & Alerts
Diagnostics Tare and Open and Close All Gates
Check the GrainGage and make sure it is free of grain or
debris.
Tap Tare.
The gates open and clear the GrainGage.
The gates close.
Sensor readings average over 4 seconds.
Mirus then uses that average to establish the zero weight
readings for the empty weigh bucket and test chamber.
Mirus also resets the EM moisture and level sensor readings to
zero.
Description
to exit Diagnostics.