H2 Stationary GrainGage User's Guide

8 .2 Enable Debug Streaming

This option enables debug streaming messages from the DSP module. Enabling this is only recommended
when troubleshooting the GrainGage with a HarvestMaster Field Service Engineer as it provides them with
a more detailed error log. Be sure to turn off debug streaming when you are not using it.
To enable debug streaming,

8 .3 Common Errors

8. 3.1 Inaccurate Plot Weight

If weight values are inaccurate, open Diagnostics and follow the steps listed below.
1. Ensure the weigh bucket of the GrainGage is in the tracks.
2. Clean inside the bucket, around the bucket, and around the load cells of the GrainGage with
compressed air.
3. Ensure there is nothing putting positive or negative tension on the weigh bucket/load cells (air hoses,
cables, overload protection pin, etc.).
4. Apply negative and positive pressure to the bucket while watching the weight values in Diagnostics.
Remove the pressure to ensure the weight returns to zero. Do this several times to ensure
repeatability.
5. Put the HarvestMaster calibration weight in the bucket with the top gate closed and check it against
the calibration weight in Diagnostics.
6. If the problem persists, contact the HarvestMaster Field Service Engineers.
Appendix B: Troubleshooting Mirus
1. Enter the Mirus Home screen.
2. Select Setup > H2 GrainGage > System.
3. Change Debug Streaming Enabled to Yes.
4. Tap Save.
Save