CAUTION: Ensure that each grounding cable lug seats flush against the surface of the
grounding points as you are tightening the screws. Ensure that each screw is properly
threaded into the grounding points. Applying installation torque to the screw when
improperly threaded may result in damage to the terminal.
CAUTION: The maximum torque rating of the grounding screws on the router is 4 lb-
in. (0.49 Nm). The grounding screws may be damaged if excessive torque is applied.
Use only a torque-controlled driver to tighten screws. Use an appropriately sized
driver, with a maximum torque capacity of 5 lb-in. or less. Ensure that the driver is
undamaged and properly calibrated and that you have been trained in its use. You may
wish to use a driver that is designed to prevent overtorque when the preset torque
level is achieved.
9. Dress the grounding cable, and verify that it does not touch or block access to router components,
and that it does not drape where people could trip on it.
Figure 21: Grounding Points on the ACX1000 and ACX1100 Router
Grounding lug
1
SEE ALSO
Prevention of Electrostatic Discharge Damage | 167
SAE 10-32 screws and washers
2