U00430/E00430
Step
Check description
1
Checking the permitted
number
U00431/E00431
Step
Check description
1
Checking the destination
unit
U00432/E00432
Step
Check description
1
Checking the sub address
password
U00433/E00433
Step
Check description
1
Checking the sub address
box
Assumed cause
Polling or sub address bul-
letin board transmission
were requested, but the
communication was inter-
rupted because the permit-
ted ID did not match. (It
occurs in the transmitting
unit.)
Assumed cause
An sub address bulletin
board transmission was
interrupted because the
specified sub address
password was not regis-
tered.
Assumed cause
A sub address bulletin
board transmission was
interrupted because the
sub address password did
not match.
Assumed cause
A sub address bulletin
board transmission
request was received but
data was notpresent in the
sub address box.
7-505
Measures
Register a valid permitted
number
Measures
Register the sub address
password in the destination
unit.
Measures
Send by using correct the sub
address password.
Measures
Set data in the sub address
box.