YC9: PF conveying clutch 1, PF conveying clutch 2, PF conveying clutch 3
YC10: PF Feedshift solenoid
YC11: PF multi feed sensor
YC14: PF top cover switch
YC15: PF paper length switch, PF paper width switch, PF set switch
YC17: PF registration motor
Connec-
Pin
tor
YC1
1
SDI(ENG_SDO)
2
SDO(ENG_SDI)
3
CLK(ENG_CLK)
4
SEL(ENG_SEL)
5
RDY(ENG_RDY)
6
ENG_PAU
7
DEK_OPN1
8
N.C
9
+3.3V2
10
GND
11
FINAL SENS
12
N.C
YC2
1
24V1
2
GND
3
GND
YC3
1
GND
2
GND
3
24V1
4
24V1
YC4
1
SDO(TAN_SDI)
2
SDI(TAN_SDO)
3
CLK(TAN_CLK)
4
SEL(TAN_SEL)
5
RDY(TAN_RDY)
6
PAU(TAN_PAU)
7
GND
8
+3.3V2
Signal
I/O
O
DC0V/
3.3V(pulse)
I
DC0V/
3.3V(pulse)
I
DC0V/
3.3V(pulse)
I
DC0V/3.3V
O
DC0V/3.3V
I
DC0V/3.3V
O
DC0V/3.3V
-
-
I
DC3.3V
-
-
O
DC0V/3.3V
-
-
I
DC24V
-
-
-
-
-
-
-
-
O
DC24V
O
DC24V
O
DC0V/
3.3V(pulse)
I
DC0V/
3.3V(pulse)
O
DC0V/
3.3V(pulse)
O
DC0V/3.3V
I
DC0V/3.3V
O
DC0V/3.3V
-
-
O
DC3.3V
Voltage
Communication data signal
Communication data signal
Communication clock signal
Communication select signal
Communication ready signal
Communication pause signal
Cassette open/close signal output
Not used
DC3.3V power input
Ground
PF conveying sensor 3: On/Off
Not used
DC24V power input
Ground
Ground
Ground
Ground
DC24V power output
DC24V power output
Communication data signal
Communication data signal
Communication clock signal
Communication select signal
Communication ready signal
Communication pause signal
Ground
DC3.3V power output