U01143/E01143
Step
Check description
1
Checking the settings
U01155/E01155
Step
Check description
1
Request for resending
2
Changing the initial value
U01160/E01160
Step
Check description
1
Request for resending
2
Changing the initial value
U01162/E01162
Step
Check description
1
Request for resending
2
Changing the initial value
Assumed cause
DCN signal is received
after sending FTT signal.
Assumed cause
DCN signal is received
after sending SPA signal.
(simplified protocol)
Line condition is poor.
(Own machine)
Assumed cause
Maximum transmission
time per line is exceeded
while receiving message.
Line condition is poor.
(Own machine)
Assumed cause
Maximum transmission
time per line is exceeded
while receiving message.
Line condition is poor.
(Own machine)
7-543
Measures
Set the G3 reception cable
equalizer in U650 [Reg G3
RX Eqr]. (Initial setting:
0dBm)
Measures
Request resending.
Change the reception speed
by executing U630 [RX
Speed].
Measures
Request resending.
Change the reception speed
by executing U630 [RX
Speed].
Measures
Request resending.
Change the reception speed
by executing U630 [RX
Speed].
2WA/2NJ/2RK
Reference
U650 Exe-
cution
Reference
U630 Exe-
cution
Reference
U630 Exe-
cution
Reference
U630 Exe-
cution