5.6.4

Connecting the signal cable

The safety circuit with the SICHARGE D charging station has been implemented using a
shielded signal cable.
Connecting the 7-pin signal cable (shielded)
There are additional signal conductors coming from SICHARGE D. Connect the conductors
according to the electrical circuit diagram. You can find the electrical circuit diagram in the
document pocket in the door of the dispenser. The following table shows the connecting
terminals and the purpose of the various conductors.
Meaning
Fast Shutdown DC3
Fast Shutdown DC4
Global Enable DC
Emergency Shutdown
1 = Terminal designation is dependent on the device configuration of SICHARGE D
2 = Remove terminals +F01-XD35:5 + +F01-XD35:6 and replace PE two-tier terminal from the accessor­
ies kit and connect
Dispenser
Operating Instructions, 10/2023, A5E52758387-AB
Conductor num­
SICHARGE D
ber
1
+F01-FA11:1
+F01-XD39:1A
2
+F01-FA11:2
+F01-XD39:2C
3
+F01-FA10:1
+F01-XD39:3A
4
+F01-FA10:2
+F01-XD39:4C
5
+F01-XD36:9A
6
+F01-XD36:1A
+F01-XD36:4C
7
+F01-XD36:2C
+F01-XD36:3A
Shield
+F01-XD35:5
+F01-XD35:6
Installation and mounting
5.6 Connecting the dispenser
1
Dispenser
+F220-XD202:3A
+F220-XD202:4C
+F220-XD202:5A
+F220-XD202:6C
+F220-XD202:1A
+F220-XD202:7A
+F220-XD202:8C
2
Shield contact to the right of
2
-XD250
55