Siemens SICHARGE D Dispenser Operating Instructions Manual page 52

Table of Contents

Advertisement

Installation and mounting
5.6 Connecting the dispenser
Preparing the conductors of the cable
You must prepare the individual conductors of the cable in order to connect them properly.
Proceed as follows:
Observe the five safety rules according to DIN EN 50110-1:2013
Working on live parts can result in severe injuries and death. Only work on the electrical
equipment when it is in a de-energized state.
1. Shorten the conductors to the final length
2. Strip the insulation from the end of the conductor so that the remaining insulation
extends up to the wire end ferrule.
3. Attach the wire end ferrule to the end of the conductor correctly
Connect the cable conductors
Connect the protective conductor of the cable first before connecting the remaining
conductors. To do this, proceed as follows:
1. Insert the protective conductor into the PE terminal -XD201:5A
2. Insert the L conductor into the L terminal -XD201:1A
3. Insert the N conductor into the N terminal -XD201:2C
52