Base Area - Siemens SICHARGE D Dispenser Operating Instructions Manual

Table of Contents

Advertisement

5.3

Base area

Properties of the base area
To ensure the stability of the dispenser, the concrete base area must meet the following
requirements:
• Level, smooth and horizontal
• Dry
• Fixed and stable, according to the ground conditions on site
NOTE
Illustrations of example
The illustrations below are examples of the installation of the charging station with
dispensers. Plan and adjust the base area together with the foundation planner in accordance
with your circumstances.
Fixing points and foundation
Fasteners such as the M12 stud bolts, nuts, washers and shims are not included in the scope
of delivery.
The feet of the dispenser are each provided with two horizontally and two vertically arranged
slots. This creates degrees of freedom for positioning on the base area. The feet do not
provide any height compensation. If height compensation is required, use the shims for
height compensation. The following figure shows the dispenser from below, including the
openings for inserting the cables.
You can find more information about installation here: SICHARGE D dispenser technical draw­
ings (https://support.industry.siemens.com/cs/ww/en/view/109822247)
Figure 5-3  Dispenser from below including openings
Dispenser
Operating Instructions, 10/2023, A5E52758387-AB
Installation and mounting
5.3 Base area
41

Advertisement

Table of Contents
loading

Table of Contents