Siemens SICHARGE D Dispenser Operating Instructions Manual page 27

Table of Contents

Advertisement

Temperature monitoring
The DC charging cables have an integrated temperature sensor in the plug. The evaluation of
these values ensures increased protection and secure transfer of the charging power. Correct
and risk-free use is guaranteed.
Performance features
Table 3-4  Performance features CCS2
Characteristic
Standard
Rated current
Rated voltage
Cable outer diameter
Power contacts
Operating cycles
Insertion and withdrawal force
The CCS2 charging cable for the 400 A boost mode is designed for a rated current of 250 A.
Thanks to the integrated temperature monitoring and adherence to limit values, it can
transfer up to 400 A for short periods. The duration of this increased current transfer depends
on the surrounding conditions, such as ambient temperature, solar radiation, cable length,
and so on.
Dispenser
Operating Instructions, 10/2023, A5E52758387-AB
Value
IEC 62196-3
250 A (400 A boost mode)
1000 V DC
(32.0 ± 0.4) mm
DC+, DC-
> 10,000
< 100 N
Description
3.5 Charging points
27

Advertisement