Allow for future expansion and equipment changes at the cross-connect
terminal.
The cross-connect terminal should have sufficient space for connecting
blocks to terminate the following wires:
ten 25-pair cables from each cabinet (the main cabinet and, if equipped,
each expansion cabinet)
nine conductors comprising the AUX cable from the main cabinet
one 25-pair cable from each QUA6 PFTU
wiring from telephone sets and trunks.
The BIX cross-connect system is recommended for use with the system.
However, use of this system is not mandatory. Other similar cross-connect
systems can also be used.
Information about the BIX cross-connect system is found in "Chapter 13 –
Installing and connecting cross-connect terminals to cabinets" on
page 147 and in the following Nortel Networks technical publications
(NTPs):
BIX In-Building Cross-Connect System Material Description
(NTP 631-4511-100)
BIX In-Building Cross-Connect System Planning
(NTP 631-4511-150)
BIX In-Building Cross-Connect System Material Installation and
Servicing (NTP 631-4511-200)