B700Xxxx Licensed Internal Code Srcs - IBM BladeCenter JS22 Problem Determination And Service Manual

Table of Contents

Advertisement

Table 11. B200xxxx Logical partition SRCs (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v See Chapter 3, "Parts listing, Type 7998," on page 235 to determine which components are CRUs and which
components are FRUs.
B200 xxxx Error
Code
Description
F003
During the startup of a partition, the
partition processor(s) did not start
the firmware within the time-out
window.
F004
Informational system log entry only.
F005
Informational system log entry only.
F006
During the startup of a partition, the
code load operation for the partition
startup timed out.
F007
During a shutdown of the partition,
a time-out occurred while trying to
stop a partition.
F008
Informational system log entry only.
F009
Informational system log entry only.
F00A
Informational system log entry only.
F00B
Informational system log entry only.
F00C
Informational system log entry only.
F00D
Informational system log entry only.

B700xxxx Licensed internal code SRCs

A B700xxxx system reference code (SRC) is an error code that is related to licensed
internal code.
Table 12 describes the error codes that may be displayed if POST detects a
problem. Suggested actions to correct the problem are also described.
Note: For problems persisting after completing the suggested actions, see
"Checkout procedure" on page 186 and "Solving undetermined problems" on page
231.
Table 12. B700xxxx Licensed internal code SRCs
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v See Chapter 3, "Parts listing, Type 7998," on page 235 to determine which components are CRUs and which
components are FRUs.
B700 xxxx Error Codes
0102
Description
System firmware detected an error. A
machine check occurred during startup.
Action
Collect the partition dump information; then, go to
"Isolating firmware problems" on page 222.
No corrective action is required.
No corrective action is required.
1. Check the error logs and take the actions for the error
codes that are found.
2. Go to "Isolating firmware problems" on page 222.
Check for server firmware updates; then, install the
updates if available.
No corrective action is required.
No corrective action is required.
No corrective action is required.
No corrective action is required.
No corrective action is required.
No corrective action is required.
Action
1. Collect the event log information.
2. Go to "Isolating firmware problems" on
page 222.
39
Chapter 2. Diagnostics