JS22 Type 7998: Problem Determination and Service Guide
Description and Action
Temporary PCI bus error detected by adapter.
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see "POST progress codes (checkpoints)" on page 88.
2. Replace any parts reported by the diagnostic program.
3. Replace the system-board and chassis assembly.
Device bus termination power lost or not detected.
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see "POST progress codes (checkpoints)" on page 88.
2. Replace any parts reported by the diagnostic program.
3. Replace the system-board and chassis assembly.
Adapter detected device bus failure.
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see "POST progress codes (checkpoints)" on page 88.
2. Replace any parts reported by the diagnostic program.
3. Replace the system-board and chassis assembly.
Temporary adapter detected device bus failure.
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see "POST progress codes (checkpoints)" on page 88.
2. Replace any parts reported by the diagnostic program.
3. Replace the system-board and chassis assembly.
Device bus interface problem.
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see "POST progress codes (checkpoints)" on page 88.
2. Replace any parts reported by the diagnostic program.
3. Replace the system-board and chassis assembly.
Device bus interface problem.
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see "POST progress codes (checkpoints)" on page 88.
2. Replace any parts reported by the diagnostic program.
3. Replace the system-board and chassis assembly.
Adapter configuration error. Go to "Performing the checkout procedure" on page
187.
Error log analysis indicates adapter failure. Go to "Performing the checkout
procedure" on page 187.
Error log analysis indicates an error attention condition. Go to "Performing the
checkout procedure" on page 187.
Error log analysis indicates that the microcode could not be loaded on the adapter.
Go to "Performing the checkout procedure" on page 187.
Error log analysis indicates a permanent adapter failure. Go to "Performing the
checkout procedure" on page 187.
Error log analysis indicates permanent adapter failure is reported on the other port
of this adapter. Go to "Performing the checkout procedure" on page 187.
Error log analysis indicates adapter failure. Go to "Performing the checkout
procedure" on page 187.
Error log analysis indicates permanent adapter failure. Go to "Performing the
checkout procedure" on page 187.