Table 24. A00-FF0 through A24-xxx SRNs (continued)
SRN
A15-22x
A15-23x
A15-24x
A15-50x
A1D-00x
A1D-02x
A1D-04x
176
JS22 Type 7998: Problem Determination and Service Guide
Description
Fan failure and Over temperature
condition.
Non-critical power problem, loss of
redundant power supply.
Power Fault specifically due to internal
battery failure.
Recoverable errors on resource indicate
a trend toward an unrecoverable error.
However, the resource could not be
deconfigured and is still in use. The
system is operating with the potential
for an unrecoverable error.
A non-critical error has been detected.
Error log analysis indicates an error
detected by the Service Processor, but
the failure could not be isolated.
A non-critical error has been detected,
an I/O (I2C) general bus error.
A non-critical error has been detected,
an internal service processor memory
error.
FRU/action
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see "POST progress codes
(checkpoints)" on page 88.
2. If no entry is found, replace the system-board
and chassis assembly.
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see "POST progress codes
(checkpoints)" on page 88.
2. If no entry is found, replace the system-board
and chassis assembly.
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see "POST progress codes
(checkpoints)" on page 88.
2. If no entry is found, replace the system-board
and chassis assembly.
1. If repair is not immediately available, reboot
and the resource will be deconfigured;
operations can continue in a degraded mode.
2. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see "POST progress codes
(checkpoints)" on page 88.
3. If no entry is found, replace the system-board
and chassis assembly.
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see "POST progress codes
(checkpoints)" on page 88.
2. If no entry is found, replace the system-board
and chassis assembly.
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see "POST progress codes
(checkpoints)" on page 88.
2. If no entry is found, replace the system-board
and chassis assembly.
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see "POST progress codes
(checkpoints)" on page 88.
2. If no entry is found, replace the system-board
and chassis assembly.