Table 11. B200xxxx Logical partition SRCs (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v See Chapter 3, "Parts listing, Type 7998," on page 235 to determine which components are CRUs and which
components are FRUs.
B200 xxxx Error
Code
Description
2054
A problem occurred during a
partition Main Storage Dump. A
mainstore dump IPL did not
complete due to a configuration
mismatch.
2058
A problem occurred during a
partition Main Storage Dump. A
mainstore dump startup did not
complete due to a copy error.
2210
Informational system log entry only.
2220
Informational system log entry only.
2250
During the startup of a partition, an
attempt to toggle the power state of
a slot has failed.
2260
During the startup of a partition, the
partition firmware attempted an
operation that failed.
2300
During the startup of a partition, an
attempt to toggle the power state of
a slot has failed.
2310
During the startup of a partition, the
partition firmware attempted an
operation that failed.
2320
During the startup of a partition, the
partition firmware attempted an
operation that failed.
2425
During the startup of a partition, the
partition firmware attempted an
operation that failed.
2426
During the startup of a partition, the
partition firmware attempted an
operation that failed.
2475
During the startup of a partition, a
slot that was needed for the partition
was either empty or the device in
the slot has failed.
2485
During the startup of a partition, the
partition firmware attempted an
operation that failed.
3000
Informational system log entry only.
3081
During the startup of a partition, the
startup did not complete due to a
copy error.
32
JS22 Type 7998: Problem Determination and Service Guide
Action
Go to "Isolating firmware problems" on page 222.
Go to "Isolating firmware problems" on page 222.
No corrective action is required.
No corrective action is required.
Check for server firmware updates; then, install the
updates if available.
Go to "Isolating firmware problems" on page 222.
Check for server firmware updates; then, install the
updates if available.
Go to "Isolating firmware problems" on page 222.
Go to "Isolating firmware problems" on page 222.
Go to "Isolating firmware problems" on page 222.
Go to "Isolating firmware problems" on page 222.
Check for server firmware updates; then, install the
updates if available.
Go to "Isolating firmware problems" on page 222.
No corrective action is required.
Check for server firmware updates; then, install the
updates if available.