Table 13. BA000010 to BA400002 Partition firmware SRCs (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v See Chapter 3, "Parts listing, Type 7998," on page 235 to determine which components are CRUs and which
components are FRUs.
Error code
BA210001
BA210002
BA210003
BA210004
BA210010
Description
Partition firmware reports a stack
underflow was caught
Partition firmware was ready before
standout was ready
A data storage error was caught by
partition firmware
An open firmware stack-depth assert
failed.
The transfer of control to the SLIC
loader failed
Action
1. Reboot the blade server.
2. If the problem persists:
a. Go to "Checkout procedure" on page
186.
b. Replace the system-board and chassis
assembly, as described in "Replacing the
Tier 2 system-board and chassis
assembly" on page 270.
1. Reboot the blade server.
2. If the problem persists:
a. Go to "Checkout procedure" on page
186.
b. Replace the system-board and chassis
assembly, as described in "Replacing the
Tier 2 system-board and chassis
assembly" on page 270.
1. If the location code reported with the error
points to an adapter, check for adapter
firmware updates.
2. Apply any available updates.
3. Check for server firmware updates.
4. Apply any available updates.
5. If the problem persists:
a. Go to "Checkout procedure" on page
186.
b. Replace the system-board and chassis
assembly, as described in "Replacing the
Tier 2 system-board and chassis
assembly" on page 270.
1. Reboot the blade server.
2. If the problem persists:
a. Go to "Checkout procedure" on page
186.
b. Replace the system-board and chassis
assembly, as described in "Replacing the
Tier 2 system-board and chassis
assembly" on page 270.
1. Go to "Checkout procedure" on page 186.
2. Replace the system-board and chassis
assembly, as described in "Replacing the
Tier 2 system-board and chassis assembly"
on page 270.