IBM BladeCenter JS22 Problem Determination And Service Manual page 164

Table of Contents

Advertisement

Table 22. 101-711 through FFC-725 SRNs (continued)
SRN
FFC
652-731
2C8
652-732
2C8
652-733
2C8 292
652-734
2C8 292
652-735
2D2 292
652-736
2D2 292
652-770
2C8 292
652-771
2C8 292
652-772
2D2 292
652-773
227
652-88x
652-89x
814-112
814
814-113
221
814-114
814
150
JS22 Type 7998: Problem Determination and Service Guide
Description and Action
A non-critical error has been detected: intermediate or system bus address parity
error. Schedule deferred maintenance. Go to "Performing the checkout procedure"
on page 187.
A non-critical error has been detected: intermediate or system bus data parity error.
Schedule deferred maintenance. Go to "Performing the checkout procedure" on page
187.
A non-critical error has been detected: intermediate or system bus address parity
error. Schedule deferred maintenance. Go to "Performing the checkout procedure"
on page 187.
A non-critical error has been detected: intermediate or system bus data parity error.
Schedule deferred maintenance. Go to "Performing the checkout procedure" on page
187.
A non-critical error has been detected: intermediate or system bus time-out error.
Schedule deferred maintenance. Go to "Performing the checkout procedure" on page
187.
A non-critical error has been detected: intermediate or system bus time-out error.
Schedule deferred maintenance. Go to "Performing the checkout procedure" on page
187.
A non-critical error has been detected: intermediate system bus address parity error.
Schedule deferred maintenance. Go to "Performing the checkout procedure" on page
187.
A non-critical error has been detected: intermediate or system bus data parity error.
Schedule deferred maintenance. Go to "Performing the checkout procedure" on page
187.
A non-critical error has been detected: intermediate or system bus time-out error.
Schedule deferred maintenance. Go to "Performing the checkout procedure" on page
187.
A non-critical error has been detected: intermediate or system bus data parity error.
Schedule deferred maintenance. Go to "Performing the checkout procedure" on page
187.
The CEC or SPCN reported a non-critical error.
1. Schedule deferred maintenance.
2. Refer to the entry MAP in this system unit system service guide, with the 8-digit
error and location codes, for the necessary repair action.
3. If the 8-digit error and location codes were NOT reported, then run diagnostics
in problem determination mode and record and report the 8-digit error and
location codes for this SRN.
The CEC or SPCN reported a non-critical error.
1. Schedule deferred maintenance.
2. Refer to the entry MAP in this system unit system service guide, with the 8-digit
error and location codes, for the necessary repair action.
3. If the 8-digit error and location codes were NOT reported, then run diagnostics
in problem determination mode and record and report the 8-digit error and
location codes for this SRN.
The NVRAM test failed. Go to "Performing the checkout procedure" on page 187.
The VPD test failed. Go to "Performing the checkout procedure" on page 187.
I/O Card NVRAM test failed. Go to "Performing the checkout procedure" on page
187.