v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v See Chapter 3, "Parts listing, Type 7998," on page 235 to determine which components are CRUs and which
components are FRUs.
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
Isolation
Symptom
Procedure Code
FSPSP02
This procedure is for
boot failures that
terminate very early
in the boot process or
when the
management card or
the VPD data on the
management card is
not operational or is
not present.
FSPSP03
A system operator or
user error has
occurred.
FSPSP04
A problem has been
detected in the
service processor
firmware.
The service processor
FSPSP05
has detected a
problem in the
platform firmware.
FSPSP06
The service processor
reported a suspected
intermittent problem.
FSPSP07
The time of day has
been reset to the
default value.
208
JS22 Type 7998: Problem Determination and Service Guide
Action
1. Replace the management card, as described in "Removing the
management card" on page 250 and "Installing the management
card" on page 252.
2. After replacing the card and installing the blade server in the chassis
unit and before rebooting the blade server or performing other
operations, ensure that the initialization of the management card
VPD occurs by waiting for the management module to discover the
blade server. Otherwise, the system might fail to IPL.
3. If the problem persists, replace the system board and chassis
assembly, as described in "Replacing the Tier 2 system-board and
chassis assembly" on page 270.
Refer to the documentation for the function you were attempting to
perform.
1. Verify that the operating system is running. If it is running, perform
an in-band firmware update, as described in "Updating the
firmware" on page 273.
2. If the problem persists, replace the system board and chassis
assembly, as described in "Replacing the Tier 2 system-board and
chassis assembly" on page 270.
1. Verify that the operating system is running. If it is running, perform
an in-band firmware update, as described in "Updating the
firmware" on page 273.
2. If the problem persists, replace the system board and chassis
assembly, as described in "Replacing the Tier 2 system-board and
chassis assembly" on page 270.
Contact IBM Support.
1. Use the chdate command to set the Virtual I/O Server date and time,
using one of the following syntaxes:
chdate [-year YYyy]
[-month mm]
[-day dd]
[-hour HH]
[-minute MM]
[-timezone TZ]
chdate mmddHHMM[YYyy|yy]
[-timezone TZ]
2. If the problem persists, replace the battery, as described in
"Removing the battery" on page 263 and "Installing the battery" on
page 264.