Table 18. CA000000 to CA2799FF checkpoints (continued)
v If the system hangs on a progress code, follow the suggested actions in the order in which they are listed in
the Action column until the problem is solved. If an action solves the problem, you can stop performing the
remaining actions.
v See Chapter 3, "Parts listing, Type 7998," on page 235 to determine which components are CRUs and which
components are FRUs.
Progress code
CA26FFFF
CA279001
CA2799FD
130
JS22 Type 7998: Problem Determination and Service Guide
Description
An extended item was required for
lpevent to complete.
The firmware update image contains an
update module that is not already on
the system.
A firmware update module is being
read.
Action
1. Go to "Checkout procedure" on page 186.
2. Replace the system-board and chassis
assembly, as described in "Replacing the
Tier 2 system-board and chassis assembly"
on page 270.
1. Look at the event log for a BA27xxxx error
code to determine if a firmware installation
error occurred.
2. If a firmware installation error did occur,
resolve the problem.
3. Retry the firmware update.
4. If the problem persists:
a. Go to "Checkout procedure" on page
186.
b. Replace the system-board and chassis
assembly, as described in "Replacing the
Tier 2 system-board and chassis
assembly" on page 270.
This checkpoint alternates in the control panel
with CA2799FF.
This pair of checkpoints might stay in the
display for up to 30 minutes with no indication
of activity other than the alternating codes. Do
not assume that the system is hung until the
alternation stops and only one of the
checkpoints remains in the control panel for at
least 30 minutes, with no other indication of
activity.
If the system is hung on this checkpoint, then
CA2799FD and CA2799FF are not alternating
and you must perform the following
procedure:
1. Shut down the blade server.
2. Restart the blade server using the
permanent boot image, as described in
"Starting the PERM image" on page 222.
3. Use the Update and Manage System Flash
menu to reject the temporary image.