Planet IGS-10020HPT-U User Manual page 317

Industrial 8-port 10/100/1000t 802.3at poe + 2-port 1g/2.5g sfp managed switch with usb console
Table of Contents

Advertisement

Action
Rate Limiter
• Port Redirect
• Mirror
• Logging
• Shutdown
• Counter
MAC Parameters
Object
SMAC Filter
match the ACE with Ethernet type.
IPv4: Only IPv4 frames can match this ACE. Notice the IPv4 frames won't
match the ACE with Ethernet type.
IPv6: Only IPv6 frames can match this ACE. Notice the IPv6 frames won't
match the ACE with Ethernet type.
Specify the action to take with a frame that hits this ACE.
Permit: The frame that hits this ACE is granted permission for the ACE
operation.
Deny: The frame that hits this ACE is dropped.
Specify the rate limiter in number of base units.
The allowed range is 1 to 16.
Disabled indicates that the rate limiter operation is disabled.
Frames that hit the ACE are redirected to the port number specified here.
The allowed range is the same as the switch port number range.
Disabled indicates that the port redirect operation is disabled.
Specify the mirror operation of this port. Frames matching the ACE are mirrored to the
destination mirror port. The rate limiter will not affect frames on the mirror port. The
allowed values are:
Enabled: Frames received on the port are mirrored.
Disabled: Frames received on the port are not mirrored.
The default value is "Disabled"
Specify the logging operation of the ACE. The allowed values are:
Enabled: Frames matching the ACE are stored in the System Log.
Disabled: Frames matching the ACE are not logged.
Note: The logging feature only works when the packet length is less than 1518(without
VLAN tags) and the System Log memory size and logging rate is limited.
Specify the port shut down operation of the ACE. The allowed values are:
Enabled: If a frame matches the ACE, the ingress port will be disabled.
Disabled: Port shut down is disabled for the ACE.
Note: The shutdown feature only works when the packet length is less than
1518(without VLAN tags).
The counter indicates the number of times the ACE was hit by a frame.
Description
(Only displayed when the frame type is Ethernet Type or ARP.)
Specify the source MAC filter for this ACE.
Any: No SMAC filter is specified. (SMAC filter status is "don't-care".)
Specific: If you want to filter a specific source MAC address with this ACE,
choose this value. A field for entering an SMAC value appears.
User's Manual of IGS-10020HPT-U
317

Advertisement

Table of Contents
loading

Table of Contents