YASKAWA VS-616PS5 Series Quick Start Manual page 62

Brushless motor drive
Hide thumbs Also See for VS-616PS5 Series:
Table of Contents

Advertisement

O1-02
Monitor Selection After Power-up
Selects the monitor to be displayed on the digital operator immediately after the power supply is turned ON.
O1-03
Reverse Torque Limit
Units for parameters and monitors related to frequency can be scaled as shown below.
Setting
1
2 ~ 39
40 ~ 3999
VS-616PS5 Installation & Quick Start Manual
Setting
1
Displays frequency reference (factory default).
2
Displays output frequency.
3
Displays output current.
4
Displays the monitor item set in O1-01.
Unit: 0.01%. Speed reference is displayed as P¨¨.¨¨
• Unit: rpm (Enter the # of poles in the motor).
• The speed reference is displayed as n ¨¨¨¨
Digits:
5th
0
The 1st through 4th digits determine the set value at 100% output frequency.
The decimal point position is set with the 5th digit of O1-03, as follows:
5th digit = 0: displayed as ¨¨¨¨
5th digit = 1: displayed as ¨¨¨.¨
5th digit = 2: displayed as ¨¨.¨¨
5th digit = 3: displayed as ¨.¨¨¨
(Example 1)
If 100% output speed is equal to 200.0 units:
Set O1-03 = "12000"
100% of this reference is displayed as 200.0 and 60% of this reference is dis-
played as 120.0.
Example 2
If 100% output speed is equal to 65.00:
Set O1-03 = "26500"
60% of this reference is displayed as 39.00.
Description
Description
4th
3rd
2nd
0
0
0
1st
0
61

Advertisement

Table of Contents
loading

Table of Contents