L5
Fault Restart
After a fault occurs, the inverter and its fault detection circuit can be reset. The automatic restart function allows
the inverter to continue operation after certain faults.
L5-01
Number of Automatic Restart Attempts
Sets the number of automatic restart attempts. Setting to "0" disables this function.
Minimum Maximum Description
0.0
10
The inverter can be set to automatically restart after the following faults occur:
Overcurrent (OC)
Overvoltage (OV)
Undervoltage PUV (UV1)
Ground fault (GF)
Regenerative transistor fault (rr)
L5-02
Automatic Restart Operation Selection
Selects whether a fault contact output is activated during automatic restart.
Setting Explanation
VS-616PS5 Installation & Quick Start Manual
Number of Automatic Restart Attempts.
No fault relay (factory default)
0
Fault relay is active
1
Default Setting
0
Default