H2 – 01 to H2 – 03
Default assignments are as follows:
Output
Parameter
Terminals
9 – 10
H2-01
25 – 27
H2-02
26 - 27
H2-03
Listed below are other settings for the digital outputs:
Setting
3
Speed Match
4
Speed Low
5
Speed High
6
Inverter Ready
7
DC Bus Undervoltage
8
Baseblock 1
9
Speed from Operator
A
Control from Operator
B
Over Torque Detection
C
Reference Loss
D
DBR Overheat
E
Fault
F
No Operation
Consult the VS-616PS5 Programming Manual for more settings and more comprehensive descriptions.
H3 – 01 to H3 – 03
These parameters set up Analog input 1 (Terminal 13), with terminal 17 common
Parameter
H3-01
Terminal 13 Signal
H3-02
Terminal 13 Reference % Gain
H3-03
Terminal 13 Reference +/- Bias
Consult the VS-616PS5 Programming Manual for the setup of Analog Input 2 and Analog Input 3.
H4 – 01 to H4 – 07
These parameters set up Analog input 1, with terminal 17 common
Parameter
H4-01
Terminal 21 Analog Output Signal
H4-02
Terminal 21 Output Gain
H4-03
Terminal 21 Output Bias
H4-04
Terminal 23 Analog Output Signal
H4-05
Terminal 23 Output Gain
H4-06
Terminal 23 Output Bias
H4-07
Output Signal Selection (both)
Consult the VS-616PS5 Programming Manual for further information on the Analog Outputs.
VS-616PS5 Installation & Quick Start Manual
Digital Outputs
Default
Setting
0
RUN output – closes while inverter is running
1
Zero Speed output – closes while output speed is less than E1-09
2
Up to Speed – closes when set speed is attained within tolerance (L4-02)
Function
Speed Matches Setting – closes when output speed = L4-01 +/- L4-02
Speed Below setting – closes while output speed < L4-01
Speed Above Setting – closes while output speed > L4-01
Ready to Run – closes when inverter has no faults or alarms
Closes when DC Bus level or power supply is below trip level
Closes when inverter output is disabled by a Baseblock command
Closes while the speed reference is supplied from the digital operator
Closes when the RUN command comes from the digital operator
Closes when torque output exceeds setting
Closes when speed reference drops 90% in less than 400 ms
Closes while Dynamic Braking resistor is overheated or on DB fault
Closes when a fault occurs
Output is not being used
Analog Input 1
Function
0: 0 to 10 VDC
Analog Outputs
Description
Default Function
1: +/-10 VDC
Units
Range
- -
0...53
- -
0.00 – 2.50
%
0.0 – 10.0
- -
0...53
- -
0.0 – 1000.0
%
0.0 – 10.0
- -
0/1
Units
Range
- -
0/1
%
0.0 – 1000.0
%
+/-100.0
Default
Default Function
5
Motor Speed
1.00
Gain = 1
0.0
Bias = 0
3
Output Current
1.00
Gain = 1
0.0
Bias = 0
0
0 – 10 VDC
Default
0
100.0
0.0
53