YASKAWA VS-616PS5 Series Quick Start Manual page 106

Brushless motor drive
Hide thumbs Also See for VS-616PS5 Series:
Table of Contents

Advertisement

No.
H5-03 Serial communication speed selection
0: No parity, 1: Even parity, 2: Odd parity
H5-04 Stopping method after communication error
0: Ramp to stop, 1: Coast to stop, 2: Fast stop, 3: Alarm only
H5-05 Serial communication timeover detection
0: Disabled , 1: Enabled
L
Protection Parameters
L2
Power Loss Ride through
L2-01
Momentary power loss ride through
0: Disabled
L2-02* Momentary power loss ride through time
L2-05
Undervoltage detection level
L3
Stall Prevention/Current Limit
L3-01
Overvoltage protection (stall prevention during decel)
0: Disabled
L4
Reference Detection
L4-01
Speed agree detection level (without sign)
L4-02
Speed agree detection width
L4-03
Speed agree detection level (with sign)
L4-04
Speed agree detection width
L4-05
Operation when frequency reference is missing
0: Stop
1: Run at 80% of previous reference
L5
Fault Restart
L5-01
Number of automatic restart attempts
L5-02
Automatic restart operation selection
0: No fault relay
L6
Torque Detection
L6-01
Overtorque detection 1 selection
0: Disabled
1: Alarm at speed agree
2: Alarm at run
L6-02
Overtorque detection 1 level
L6-03
Overtorque detection 1 time
L6-04
Overtorque detection 2 selection
0: Disabled
1: Alarm at speed agree
2: Alarm at run
L6-05
Overtorque detection 2 level
L6-06
Overtorque detection 2 time
L7
Torque Limit
L7-01
Forward torque limit
L7-02
Reverse torque limit
L7-03
Regenerative forward torque limit
L7-04
Regenerative reverse torque limit
L8
Hardware Protection
L8-01
Protection selection for internal DB resistor
0: Not Provided
L8-02
OH pre-alarm level
*
Default for Parameter L2-02 is model dependant. For clarification, please refer to Parameter 02-04: Inverter Model Selection
Page D-10
Parameter Description
1: Enabled
1: Fault relay active
3: Fault at speed agree
4: Fault at run
3: Fault at speed agree
4: Fault at run
1: Provided
Unit
Setting Range
1
0-2
1
0-3
1
0,1
-
0
s
0.0~2.0
V
150~210
-
0~1
%
0.0~100.0
%
0.0~100.0
%
0~±100.0
%
0.0~100.0
-
0/1
-
0~10
-
0/1
-
0~4
%
0~300
s
0.0~10.0
-
0~4
%
0~300
s
0.0~10.0
%
0~300
%
0~300
%
0~300
%
0~300
-
0/1
ºC
50~110
VS-616PS5 Installation & Quick Start Manual
Access
User
Default
Level
Setting
0
A
3
A
1
A
0
B
0.7
B
190
A
1
B
0.0
B
2.0
B
0.0
A
2.0
A
0
A
0
B
0
B
0
B
150
B
0.1
B
0
A
150
A
0.1
A
150
B
150
B
150
B
150
B
0
A
95
A

Advertisement

Table of Contents
loading

Table of Contents