Terminal 5
OPEN
CLOSED
OPEN
CLOSED
NOTE: Up to nine presets are available in advanced modes.
D1 – 09
Preset JOG Speed Reference
The JOG speed reference is set in the same manner as the other presets. This is the speed at which the motor will
run when the digital operator is in LOCAL mode and the JOG button is pressed.
To use the JOG speed reference when the digital operator is in REMOTE (or disconnected), close terminal 7 at the
same time as the RUN command is applied. The JOG speed command has priority over all other reference com-
mands.
VS-616PS5 Installation & Quick Start Manual
Terminal 6
OPEN
Speed Reference 1 - determined by B1-01
OPEN
Speed Reference 2 - active only if H3-05 and H3-09 is not equal to 0
CLOSED
Speed Reference 3 – D1-03 supplies speed reference
CLOSED
Speed Reference 4 – D1-04 supplies speed reference
Selected Speed Reference
37