Error Log & Event Log

About

The Error Log and Event Log information displays contain a historical record of triggered
Error Event Codes and related information. The Error Log and Event Log are similar displays
used on different console models. The P10, P20, and P30 use the Error Log display and the
P62, P80, and P82 use the Event Log.
Always refer to the Error Log or Event Log when troubleshooting an issue. The error logs will
contain any triggered error code events and related information. You can then refer to
Code Troubleshooting Guide
vice for assistance, refer to the Error Log or Event Log for additional information to help the rep-
resentative resolve the issue.
Error event codes are sequentially stored as a table in memory in a First-In Last-Out basis, the
newest error code is stored in the number one position pushing any current error codes down
one position. When the memory is full, the oldest error code is pushed off the stack and
removed from memory.
When an error event is detected, the error code and related information will be stored into the
error log. However, when multiple instances of the same error code event occur within the
same Hour or Odometer reading, only the first occurrence will be logged. Either the one hour
limit is exceeded, or a change to the Odometer mileage, or a different intervening error code is
logged must occur before the same repeating error code is logged again.
Note: Multiple repeating instances of the same error code event occurring during
the same Hour or Odometer reading will only be logged as a single error code event.
Accessing the Error Log & Event Log
Access either the Error Log or Event Log for your particular console:
P10, P20, and P30: access Information Display ( 6,5) > select Error Log.
TIP: Deleting Error Codes from the Error Log: Press and hold the PAUSE/RESET
key for a minimum of 6 seconds to open the Error Log and view all logged error codes.
If there are no logged error codes, the "Stuck Key" message will show. To remove
error codes, select the error code and press/hold the QUICK START key until the
"NO ERRORS" message shows.
P62, P80, and P82: Access Hardware Validation ( 5,1,7,6,5,7,6,1) > select About >
Event Log
Note:  Unlike the Error Log, error codes cannot be manually removed from the CPA
Event Log.
1
Control Processing Assembly
Experience Series 800 Line EFX
to help resolve the issue. Also, when calling Precor customer ser-
6 Troubleshooting
Error Log & Event Log
Error
1
CPA
128

Advertisement

Table of Contents
loading

This manual is also suitable for:

Efx800-16 base

Table of Contents