Telemetry : Servo sensor [Current]
in-flight current, operating angle, and internal
If you forget to connect the servo wiring during
fuselage assembly, or the servo was disconnected,
an alarm can be activated at the transmitter.
Max. and min. values
s i n c e t h e p o w e r
was turned ON will
display.
When the Alarm or
Vibrator options are
activated, the servo
connection will
display.
*This alarm and display is limited to the S.BUS
servos connected to the servo sensors.
↑ An upward arrow
indicates the alarm
will sound when the
current reaches above
your set value.
↓ A downward arrow
indicates the alarm
will sound when the
current reaches below
your set value.
Alarm is chosen from
Buzzer, Voice, and
Inhibit.
Allows Speech to be
turned ON or OFF.
< Linkage menu >
110
*Servo sensor must be installed in the aircraft.
Tapping this and selecting
"Buzzer" will cause the device
t o s o u n d a n a l a r m w h e n
servos are not connected.
Vibrator is choices are
type1-3, and Inhibit.
Tap here and go to the
Servo 2 settings page.
(Display and settings
content is the same as
Servo 1.)
Tapping this will
take you to the
settings screen for
the current alarm
Tapping this and selecting
"Each type" will cause the
device to vibrate when servos
are not connected.
Sets the current on
which the alarm
operates.
Initial value: ↑ 10.0A ↓ 0.0A
Adjustment range 0.0A~10.0A
( ↑ Limit ≧ ↓ Limit)