Alcatel-Lucent 1665 Installation Manual page 270

Data multiplexer
Hide thumbs Also See for 1665:
Table of Contents

Advertisement

Operational tests
........................................................................................................................................................................
................................................................................................................................................
4
Select
................................................................................................................................................
5
Use the Cross-Connection Wizard to enter a new cross-connection at the STS-1 rate,
UPSR Ring Add/Drop, between m1-1-1 and fn1-1 (fn will be a,b,c or d depending on the
slot where the DS1, DS3, or TMUX CP is located).
This command creates a cross-connection to map 28 DS1s of a DS1circuit pack or the first
DS3 of a DS3/EC1 or TMUX circuit pack in a Function unit slot(s) to the first STS-1 of
the Main OLIUs.
................................................................................................................................................
6
Select
................................................................................................................................................
7
After screen appears, click the "+" next to ASAP Type System, Highlight DEFAULT and
click the Provision Button.
................................................................................................................................................
8
After the screen on the right appears, click on the Alarm Level on the Power/Fuse
Failure row and change the alarm severity to Major.
................................................................................................................................................
9
Click APPLY.
................................................................................................................................................
10
Unseat one of the LNW7/LNW8/LNW801, LNW16/LNW19B or LNW18/LNW20 circuit
packs from the function group being used.
Result:
Note:
time is 2 seconds.
................................................................................................................................................
11
Press the ACO pushbutton on the SYSCTL.
Result:
The MN audible alarm clears.
........................................................................................................................................................................
7 - 4
Configuration > Cross-Connections
Configuration > Alarms > Alarm Severity Assignment Profile
Activated office alarms: MN visual, MN audible.
Alarms will not be activated until the alarm delay time has passed. The default
Activated office alarm: MN visual.
.
Office alarm test
.
Alcatel-Lucent 1665 DMX R9.0
365-372-304R9.0 Issue 2
July 2010