Alcatel-Lucent 1665 Dmx High-Capacity Shelf Mounting Bracket Positions - 19-Inch Frame - Alcatel-Lucent 1665 Installation Manual

Data multiplexer
Hide thumbs Also See for 1665:
Table of Contents

Advertisement

Physical installation
............................................................................................................................................................................................................................................................
Figure 2-2 Alcatel-Lucent 1665 DMX high-capacity shelf mounting bracket
........................................................................................................................................................................................................................
3
Determine the position that the Alcatel-Lucent 1665 DMX high-capacity shelf will be
mounted.
mounting arrangements" (p. 2-7)
bottom of the bay and add shelves from bottom to top.
Note:
(Clogged Filter Alarm ON) and "CF ALM OFF" (Clogged Filter OFF). The fan ships
with the switch in the disable position which prevents the filter alarm from working.
To enable the filter alarm, remove the fan unit from the Alcatel-Lucent 1665 DMX
high-capacity shelf, move the switch to the "CF ALM ON" position and then reinstall
the fan unit in the shelf.
........................................................................................................................................................................................................................
4
Position the Alcatel-Lucent 1665 DMX high-capacity shelf in the frame and secure it to
the frame using the thread-forming screws included with the shelf (4 screws per side).
Tighten the screws to 21 in.-lb. (minimum)/30 in.-lb. (maximum).
............................................................................................................................................................................................................................................................
2 - 6
positions — 19-inch frame
TIGHTEN SCREWS
TO 10 IN.-LB.
Figure 2-3, "Typical Alcatel-Lucent 1665 DMX high-capacity shelf bay
There is a switch on the fan unit controller board. It is labeled "CF ALM ON"
Alcatel-Lucent 1665 DMX high-capacity shelf installation
shows the recommended mounting positions. Start at the
Alcatel-Lucent 1665 DMX R9.0
365-372-304R9.0 Issue 2
July 2010